    Seawater Reverse Osmosis

    Containerized-C Series SWRO Equipment - C series watermaker is designed to install the pretreatment system, RO system, chemical cleaning system and chemical dosing system all into the container. Containerized design minimize the site installation and erecting time of the desalination system. No need extra roof for the system.Containerized

    Containerized-C Series SWRO Equipment

    C series watermaker is designed to install the pretreatment system, RO system, chemical cleaning system and chemical dosing system all into the container. Containerized design minimize the site installation and erecting time of the desalination system. No need extra roof for the system.

    Containerized system also make the transportation much easier.
    To ensure the reliability of the watermaker, the core parts are from the well-known manufacturers in water treatment area, such as Danfoss, Pentair, Toray, Hydranautics, Siemens, Schneider, etc.
    C series watermaker are designed and manufactured on the basis of the induCstrial standard: ASME, ASTM, IEC, etc.
    1) Containerized design minimize the site installation and shorten the erecting time.
    2) Containerized system save cost from transportation and site civil works.
    3) Simple process, feed pump is used as backwash pump for sand filter.
    4) Automatically backwash system for sand filter.
    5) 3 step fi ltering ensure the safe operation of high pressure pump, energy recovery device and RO membrane.
    6) Super duplex high pressure pump using axial piston principle from Danfoss, higher efficient, lighter, more compact than common plunger pump, and only one service is needed for up to 3 year.
    7) Super duplex energy recovery device using isobaric pressure exchanger principle from Danfoss, much higher effi cient than energy recovery turbine, and only one service is needed for up to 3 year.

    Note:
    1) The rated product fl ow and rated recovery rate are based on the design feed (35,000 ppm, 20°C standard seawater), if the feed TDS is lower, higher product and higher recovery rate could be available; If the TDS is higher, the capacity might be cut and the recovery rate might be lower (for C-400E and above) to ensure the safe operation, contact us for details.
    2) As the system has no feed pump, an intake pump or feed pump should be added to provide the required pressure.
    3) The normal operating system pressure shall be above the minimum pressure. If higher pressure above 70bar is needed, please contact us for solution.
    4) The power consumption at 70 bar, normally lower. The power of intake pump and/or feed pump are not included.
    5) Other input voltage and frequency is available on request.