DuPont™ IntegraTec™ XP 51 IP IG Ultrafiltration Membrane – Containerized UF Solution

DuPont™ IntegraTec™ XP 51 IP IG Ultrafiltration Membrane – Containerized UF Solution
1. Product Overview
The DuPont™ IntegraTec™ XP 51IP IG is a high-performance ultrafiltration (UF) module specifically engineered for skid-mounted and containerized water treatment solutions.
Designed for Out-In pressurized filtration, this module combines DuPont's proven XP hydrophilic PVDF membrane technology with an innovative end-cap design for easy installation and scalability.

2. Core Features & Benefits (USP)
Superior Durability: Utilizes XP Hydrophilic PVDF Fiber for excellent resistance to fouling and chlorine, ensuring a long membrane lifetime.
High Efficiency: Offers excellent filtration permeability and a high recovery rate, even with high air scouring tolerance.
Easy Maintenance: Features "Easy cleaning and wettability" with reduced chemical consumption during maintenance cleanings.
Optimized Design: Short module design suits height-restricted or containerized installations. The innovative end cap allows for direct coupling of modules in IP skids, simplifying assembly and scaling.
3. Key Applications
This module is ideal for the following industries and processes:
Municipal: Drinking water treatment and wastewater filtration.
Industrial: Utility water, wastewater reuse, and RO (Reverse Osmosis) pretreatment.
High-Security Filtration: Provides high log removal rates for bacteria and viruses.
4. Technical Specifications
The following table outlines the critical physical and operational parameters of the module.
| Parameter | Metric Value | Imperial Value |
|---|
| Part No. / GMID | 12091626 | - |
| Membrane Material | PVDF (Polyvinylidene Fluoride) | - |
| Active Area | 51 m² | 549 ft² |
| Module Length (Overall) | 1,991 ± 30 mm | 78.4 ± 0.1 inch |
| Module Diameter | 225 mm | 8.9 inch |
| Shipping Weight | 69 kg | 152 lbs |
| Pore Size | 0.03 μm | - |
5. Suggested Operating Conditions
To ensure optimal performance and longevity, please adhere to the following operating guidelines:
Temperature Range: 1°C to 40°C (34°F to 104°F)
Operating pH: 2 to 11 (Cleaning pH up to 12)
Filtration Flux: Up to 110 L/(m²·h) (64.5 gfd)
Backwash Flux: Up to 120 L/(m²·h) (70.6 gfd)
Max Inlet Pressure: 6.25 bar (90.7 psi) at 20°C
Max Filtration TMP: 2.1 bar (305 psi)
Backwash Type: Air scour with liquid backwash

6. Important Notes
Pressure Control: Avoid abrupt pressure variations. The maximum allowable pressure change rate is 0.5 bar/s.
Certification: Certified drinking water modules require specific conditioning procedures prior to producing potable water.
Documentation: For detailed process design and assembly, please refer to the official DuPont manuals