LCX-10H High-Temperature Disinfection Type China EDI stacks The First Choice for High-Temperature Ultrapure Water Preparation in Small and Medium-Capacity Scenarios

Recently, many friends in food processing and pharmaceutical intermediate production have been asking which EDI stacks are suitable for temperature-resistant needs in small and medium-capacity scenarios. Today, I must recommend the LCX-10H – this high-temperature disinfection type China EDI stacks from LC PURE. It can stably produce water at 5-60℃ and even withstand high-temperature disinfection at 85℃, making it extremely popular in small and medium-sized factories that require frequent sterilization. There’s no need to worry about the impact of temperature on the equipment at all.
When choosing high-temperature China EDI stacks, it’s essential to understand the parameters thoroughly, especially temperature resistance and water production capacity. I’ve organized the key parameters of the LCX-10H into a table, so you can easily check against your own needs:
Parameter Category | Specific Value | Remarks |
---|
Flow Range | 0.8-1.2m³/h | Suitable for high-temperature water needs of small and medium-sized factories |
Operating Current | 2.5A (adjustable 0-6A) | Low energy consumption and stable operation at high temperatures |
Operating Voltage | 0-200VDC | Compatible with industrial high-frequency DC power supplies |
Maximum Power | 1.2KW/H | 20%+ more energy-efficient than ordinary high-temperature water treatment equipment |
Shipping Weight | 50KG | Flexible installation, no need for heavy-duty brackets |
Overall Dimensions | 605mm (Height) × 315mm (Width) | Small floor space, can be placed in workshop corners |
Total Length A | 370mm | Suitable for compact installation spaces |
Left-Right Positioning Center Distance | 215mm | Standardized installation holes for easy fixation |
Front-Back Positioning Center Distance | 290mm | Convenient for pipeline connection, reducing modification work |
Fresh Water Inlet/Outlet Connector | 1-1/4″PT Female Thread | Good sealing performance, no liquid leakage at high temperatures |
Concentrated Water Inlet/Outlet Connector | 3/4″PT Female Thread | Compatible with common high-temperature pipeline specifications |
Product Water Quality | ≥10MΩ·CM | Meets high-temperature ultrapure water standards for food and pharmaceutical industries |
As a high-temperature-specific China EDI stacks, the LCX-10H has clear requirements for inlet water. Only when these requirements are met can the equipment’s service life and water production effect be guaranteed – never overlook this:
Inlet Water Source: Must be reverse osmosis (RO) product water (substandard pretreatment will directly damage the membrane stack)
Inlet Conductivity: ≤10μS/cm; ≤5μS/cm when containing CO₂ and silicon (the lower the conductivity, the smaller the membrane stack loss)
Temperature Range: 5-60℃ (can reach 85℃ for a short time during disinfection, but cannot exceed 60℃ for long-term operation)
Inlet Water Pressure: 0.1-0.3MPa (unstable pressure will cause uneven water flow distribution)
Total Chlorine Content (Cl₂): <0.02ppm (chlorine oxidizes ion exchange resins and must be completely removed)
Heavy Metals (Fe/Mn/S⁻): All <0.01ppm (prone to forming precipitates and clogging membrane pores at high temperatures)
pH Value: 7-8 (neutral range to avoid equipment corrosion or silicon precipitation)
Total Hardness (as CaCO₃): <0.5ppm (high hardness leads to scaling at high temperatures, affecting desalination efficiency)
Total Organic Carbon (TOC): <0.5ppm (calculated as C, to prevent resin contamination from high-temperature decomposition)
Silicon Content (as SiO₂): <0.5ppm (silicon is a "key area" for high-temperature scaling and must be strictly controlled)
Oxidizing Substances/Oil/Fat: Not detected (oxidizing substances damage resins; oil/fat clogs membrane pores, directly causing equipment failure)
After the inlet water meets the standards, setting operating parameters reasonably is essential to maximize the performance of the LCX-10H China EDI stacks. Remember these standards:
Recovery Rate: 85-95% (it is recommended to control it at around 90%; concentrated water can be recycled to the RO inlet water tank for reuse without wasting water)
Maximum Inlet Water Pressure: ≤0.5MPa (maintain 0.2-0.3MPa during daily operation; open the pressure relief valve when exceeding 0.4MPa)
Pressure Drop at Normal Flow: 0.1-0.3MPa (abnormal pressure drop may indicate a clogged pipeline and requires timely inspection)
Maximum Inlet Water Temperature: 60℃ (cannot exceed this for continuous operation; reduce the flow slightly when raising the temperature for a short time)
Disinfection Temperature/Frequency: 85℃ (single disinfection), ≥150 times (disinfect 2-3 times a month, sufficient for the equipment’s warranty period)
Maximum Inlet Conductivity: ≤5μS/cm (the system will automatically alarm and shut down if exceeded during operation; do not force startup)
Minimum Product Water Quality: ≥10MΩ·CM (check the inlet water or membrane stack status if it is lower than this value)
Let me share a real case. A food factory in Jiangsu that produces fruit juice concentrates previously used ordinary EDI stacks to treat high-temperature cleaning water, but encountered many problems: water production became unstable when the temperature exceeded 35℃; the equipment had to be disassembled for manual disinfection every month, which was time-consuming and prone to contamination; and the wastewater treatment cost was high.
After switching to the LCX-10H China EDI stacks, the changes were particularly obvious:
It can stably produce water at 5-60℃, so the fruit juice production line no longer needs to shut down due to water temperature fluctuations, increasing production efficiency by 12%;
High-temperature disinfection at 85℃ can be performed directly, with 3 disinfections per month without disassembling the equipment. This saves 2 maintenance working hours and avoids the risk of manual contamination;
Concentrated water is recycled to the RO system, increasing the water resource utilization rate from 72% to 91% and saving over 6,000 yuan in monthly wastewater treatment costs.
The factory director told me: "If I had known that high-temperature China EDI stacks are so worry-free, I wouldn’t have struggled with ordinary equipment before. It was both costly and affected production!"
Many friends are worried that EDI stacks are difficult to maintain under high-temperature conditions. In fact, the LCX-10H is very easy to maintain. Just remember these 5 small tips, and even beginners can handle it:
Keep an Eye on Inlet Water Quality: Before starting the machine each time, check the inlet water temperature (do not exceed 60℃) and conductivity (≤5μS/cm). If the standards are exceeded, treat the RO product water first to prevent unqualified water from entering the membrane stack;
Standardize Disinfection Operations: During disinfection at 85℃, first reduce the flow to 0.6m³/h. After disinfection, slowly cool down to below 60℃ before restoring the normal flow to avoid damaging the membrane due to excessive temperature difference;
Regularly Check Pressure and Flow: Check the pressure gauge (the pressure at the fresh water inlet and outlet should be 0.15MPa higher than that at the concentrated water inlet and outlet) and flowmeter (maintain 0.8-1.2m³/h) every day. If the values are incorrect, adjust the control valve – it only takes a few minutes;
Don’t Neglect Power Supply Maintenance: Be sure to use a DC power supply with "one-to-one control". Check the current (2.5A) and voltage (0-200VDC) every month, and do not let the power supply overload in high-temperature environments;
Inspect Connector Sealing: Threaded connectors are prone to loosening at high temperatures. Gently tighten the fresh water and concentrated water connectors with a wrench every month to ensure no liquid leakage and avoid safety hazards caused by high-temperature water leakage.
Absolutely! Its flow range is 0.8-1.2m³/h, so 1 ton is right in the middle. Even if the short-term peak reaches 1.2 tons, it can handle it, and there’s no need to add additional equipment.
The initial investment is slightly higher than that of ordinary models, but it’s more cost-effective in the long run: ordinary EDI requires frequent acid-base replacement and manual disinfection, with monthly maintenance costs of over 3,000 yuan; the LCX-10H does not require regeneration and saves trouble in disinfection, with monthly maintenance costs of only about 800 yuan. The price difference can be recovered in 3 months.
No major modifications are needed! Its fresh water interface is 1-1/4″PT female thread, and the concentrated water interface is 3/4″PT female thread, which can be directly connected to the high-temperature pipelines of most factories. Professional installers can complete the installation in one day without delaying production.
Engineer Liu from a food processing factory in Shandong: "We use the LCX-10H to treat 45℃ cleaning water, and the product water quality is stably maintained at 11MΩ·CM. High-temperature disinfection at 85℃ is very convenient without disassembling the equipment. China EDI stacks are much more reliable than ordinary high-temperature equipment!"
Manager Wang from a pharmaceutical factory in Zhejiang: "Previously, ordinary EDI had problems at 38℃. After replacing with the LCX-10H, it has operated without faults at 40℃ for half a year, and the number of disinfections is also sufficient. We have saved nearly 80,000 yuan in maintenance costs a year. It’s really worth it!"
In addition to the LCX-10H, LC PURE has many models suitable for different scenarios. You can choose according to your needs:
LCX Series Industrial General-Purpose: LCX-05T, LCX-10T, LCX-20T, LCX-30T, LCX-38T, LCX-45T, LCX-50T, LCX-55T (Water production: 0.4-7.3m³/h);
LCM Series Industrial General-Purpose: LCM-3T, LCM-5T (Water production: 2.8-5.3m³/h);
Laboratory MINI Series: MINI-20, MINI-60, MINI-100, MINI-150, MINI-200, MINI-250, MINI-300 (Water production: 20-300L/h);
LC Classic Series: LC-300, LC-500, LC-1000, LC-2000, LC-3000, LC-4000, LC-5000 (Water production: 0.3-5.2m³/h);
LCX-H High-Temperature Disinfection Type: LCX-05H, LCX-10H, LCX-20H, LCX-30H, LCX-38H, LCX-45H (High temperature resistance up to 60℃, can be disinfected at 85℃).
For more models, please click: https://www.fgwater.com/China-EDI-stacks/587.html