Ionpure IP-LXM55Z-5 CEDI Module with 9.0–10.0 m³/h Design Flow

1.Product OverviewThe Ionpure IP-LXM55Z-5 is an industrial continuous electrodeionization (CEDI) module designed to produce a continuous flow of high-purity deionized water from RO permeate without chemical regeneration. It is intended for boiler makeup water in power plants, hydrocarbon

Category: Evoqua Electrodeionization EDI Stack Modules
Ionpure IP-LXM55Z-5 CEDI Module with 9.0–10.0 m³/h Design Flow

1. Product Overview

 The Ionpure IP-LXM55Z-5 is an industrial continuous electrodeionization (CEDI) module designed to produce a continuous flow of high-purity deionized water from RO permeate without chemical regeneration. It is intended for boiler makeup water in power plants, hydrocarbon processing, chemical processing, and other high-purity water applications.


image.png


2. PRODUCT SPECIFICATIONS

Item

Specification

Brand

Ionpure

Model

IP-LXM55Z-5

Product type

Continuous electrodeionization (CEDI) module

Ordering part number

W3T653071

Dimension L

1062 mm (41.81 in)

Dimension C

887 mm (34.9 in)

Shipping weight

225 kg (496 lb), including shipping crate

Operating weight

190 kg (419 lb)

Compliance

CE marked; wetted materials comply with NSF 14 and NSF 61 requirements

Manufacturing systems

ISO 9001 and ISO 14000 quality and environmental management systems

3. OPERATING PARAMETERS

Parameter

Value / Range

Minimum flow rate

3.1 m³/h (13.75 gpm)

Design flow rate

9.0–10.0 m³/h (40–44 gpm)

Feed water source

RO permeate

Feed water conductivity equivalent, including CO₂ and silica

< 40 μS/cm

Feed water temperature

5–45°C (41–113°F)

Inlet pressure

1.4–6.9 bar (20–100 psig)

Feed water pH

4–11

Maximum total chlorine, as Cl₂

< 0.05 ppm

Iron, as Fe

< 0.01 ppm

Manganese, as Mn

< 0.01 ppm

Sulfide, as H₂S

< 0.01 ppm

Total hardness, as CaCO₃

< 1.0 ppm

Dissolved organics, TOC as C

< 0.5 ppm

Silica, as SiO₂

< 1.0 ppm

Typical recovery

90–95%

Typical DC voltage

0–400 V

Typical DC amperage

1.0–6.0 A

Installation environment

Indoor installation with no direct sunlight

Maximum ambient temperature

45°C (113°F)

Recovery, DC voltage, DC amperage, and product resistivity are typical module performance values. Actual performance may vary depending on site-specific operating conditions and can be evaluated using the Ionpure IP-Pro projection software.Actual performance may be determined using the Ionpure IP-Pro projection tool. No separate testing or chemical-cleaning conditions are specified in this product data sheet.

4. Key Features & Benefits

  • Continuous high-purity water production: Produces a continuous flow of high-purity deionized water without the downtime or chemical regeneration associated with conventional deionization methods.

  • High design flow capacity: A design flow range of 9.0–10.0 m³/h (40–44 gpm) supports industrial high-purity water system planning.

  • Typical product water quality: Provides a typical product resistivity of 17 MΩ·cm. Actual performance may be evaluated using the Ionpure IP-Pro projection tool.

  • Feed water chlorine limit: The specified feed water requirement for total chlorine is ≤ 0.05 ppm as Cl₂, together with the other applicable feed water requirements.

5. Key Applications

  • Boiler makeup water for power plants

  • Hydrocarbon processing

  • Chemical processing

  • Other high-purity water applications


Project Inquiry · Technical & Commercial

Send Your Water Treatment Requirement

Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Feedwater source / available analysis
  • Design flow or required production capacity
  • Target product-water quality or process duty
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.