Ultrafiltration (UF)
DuPont™ IntegraTec™ XP 77 IP Ultrafiltration Module for Drinking Water, Industrial Water, Wastewater Reuse and RO Pretreatment | High-Recovery, Fouling-Resistant PVDF Membrane
Product DescriptionProven Ultrafiltration Performance for Municipal and Industrial Water TreatmentThe DuPont™ IntegraTec™ XP 77 IP is a pressurized hollow-fiber ultrafiltration module engineered for municipal drinking water, industrial utility water, wastewater reuse, municipal wastewater filtrati
Product Description
Proven Ultrafiltration Performance for Municipal and Industrial Water Treatment
The DuPont™ IntegraTec™ XP 77 IP is a pressurized hollow-fiber ultrafiltration module engineered for municipal drinking water, industrial utility water, wastewater reuse, municipal wastewater filtration, and reverse osmosis pretreatment. Combining proven membrane technology with a rack-ready module design, it delivers dependable water quality, high operating recovery, and efficient performance across demanding treatment environments.
At the core of the XP 77 IP is DuPont’s proven hydrophilic PVDF hollow-fiber membrane. Its 0.03 μm nominal pore size provides effective removal of colloidal particles and high log reduction of bacteria and viruses, helping improve treated-water quality and protect downstream processes. Excellent permeability supports productive filtration, while superior resistance to fouling and chlorine enables reliable operation and efficient membrane cleaning.
The module provides 77 m² (829 ft²) of active membrane area and supports a maximum filtration flow of 8.5 m³/h (37.4 gpm) within the specified operating limits. Its outside-in, dead-end filtration configuration is designed for high-recovery applications requiring consistent performance and a practical system footprint.
Designed for Scalable, Low-Maintenance Systems
An innovative end-cap design enables direct module coupling in DuPont™ IntegraTec™ IP rack systems, simplifying installation and supporting straightforward capacity expansion. High tolerance to air scouring promotes effective backwashing and stable operating recovery, while the recommended maintenance-cleaning protocol helps reduce chemical consumption.
Constructed with robust wetted materials, the IntegraTec™ XP 77 IP is designed for long service life and low routine maintenance. It provides plant operators and system designers with a proven ultrafiltration solution for new installations, capacity expansions, and pretreatment systems.
Key Product Advantages
Proven hydrophilic PVDF membrane: Delivers strong permeability, wettability, and long-term filtration performance
Reliable contaminant removal: Provides high removal of colloidal particles, bacteria, and viruses
Superior fouling resistance: Helps maintain stable performance in challenging feedwater conditions
High chlorine tolerance: Supports effective cleaning and long-term membrane operation
High operating recovery: Air-scour-assisted backwashing improves cleaning efficiency and water recovery
77 m² active membrane area: Maximizes filtration productivity in rack-based treatment systems
Scalable rack integration: Direct module coupling simplifies system assembly and future expansion
Reduced chemical consumption: Optimized maintenance-cleaning procedures help lower chemical demand
RO membrane protection: Reduces suspended solids and microbial loading before reverse osmosis treatment
Durable construction: Robust module materials support a long operating life
Easy installation and maintenance: Designed to simplify commissioning and routine plant operation
Recommended Applications
Municipal drinking water production
Industrial utility water treatment
Industrial wastewater recycling and reuse
Municipal wastewater filtration
Reverse osmosis pretreatment
Process water treatment
High-recovery, rack-mounted ultrafiltration systems
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product model | DuPont™ IntegraTec™ XP 77 IP |
| Part number / GMID | 12091629 |
| Filtration mode | Pressurized, outside-in |
| Membrane configuration | Hollow fiber |
| Membrane material | Hydrophilic PVDF |
| Nominal membrane pore size | 0.03 μm |
| Operating process | Dead-end filtration |
| Active membrane area | 77 m² / 829 ft² |
| Maximum filtration flux | 110 L/(m²·h) / 64.5 gfd |
| Maximum filtration flow | 8.5 m³/h / 37.4 gpm |
| Typical filtration TMP | 0.4–1.5 bar / 5.8–21.8 psi |
| Typical backwash TMP | 0.6–2.0 bar / 8.7–29.0 psi |
| Backwash method | Air scour with liquid backwash |
| Operating temperature | 1–40°C / 34–104°F |
| Operating pH range | 2–11 |
| Cleaning pH range | 2–12 |
| Maximum inlet pressure | 6.25 bar at 20°C / 90.7 psi |
| Maximum particle size | 300 μm |
| Overall module length | 2,491 ± 3 mm / 98.1 ± 0.1 in |
| Module diameter | 225 mm / 8.9 in |
| Empty weight | 66 kg / 146 lb |
Product Summary
The DuPont™ IntegraTec™ XP 77 IP is a high-recovery ultrafiltration module for municipal drinking water, industrial utility water, wastewater reuse, municipal wastewater filtration, and RO pretreatment. It features a 0.03 μm hydrophilic PVDF hollow-fiber membrane, 77 m² of active filtration area, and a maximum filtration flow of 8.5 m³/h. Its fouling resistance, chlorine tolerance, air-scour-assisted backwashing, scalable rack design, and robust construction make it a reliable choice for municipal and industrial water treatment systems.
FAQ Content
What is the DuPont™ IntegraTec™ XP 77 IP used for?
The IntegraTec™ XP 77 IP is designed for municipal drinking water production, industrial utility water treatment, industrial wastewater reuse, municipal wastewater filtration, and pretreatment before reverse osmosis systems.
What membrane technology does the XP 77 IP use?
It uses hydrophilic PVDF hollow-fiber membrane technology with a nominal pore size of 0.03 μm. The membrane offers excellent filtration permeability, fouling resistance, chlorine tolerance, wettability, and cleanability.
What contaminants can the XP 77 IP remove?
The module is designed to provide high removal of colloidal particles and high log reduction of bacteria and viruses. Actual removal performance depends on feedwater characteristics, system design, and operating conditions.
What is the filtration capacity of the XP 77 IP?
The module contains 77 m², or 829 ft², of active membrane area. Its specified maximum filtration flow is 8.5 m³/h, or 37.4 gpm. This value is an operating limit rather than a guaranteed design flow; actual capacity should be determined according to feedwater quality and process conditions.
Why is the XP 77 IP suitable for RO pretreatment?
Its 0.03 μm ultrafiltration membrane reduces colloidal particles and microbial loading before water enters the RO system. This helps protect downstream membranes and supports more stable RO operation.
Can the XP 77 IP be used in expandable treatment systems?
Yes. The module’s end-cap design supports direct coupling in DuPont™ IntegraTec™ IP rack systems, enabling simple assembly and scalable plant expansion.
Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target