System Overview
The FG-BWRO-5000 is a fully skid-mounted, automatic 5 m³/h (5,000 LPH) brackish water reverse osmosis system engineered for continuous treatment of brackish well water and underground salty water. Built on a 304 stainless steel frame with FRP pressure vessels and UPVC piping, the system integrates multi-stage pretreatment, precision filtration, antiscalant dosing, and high-pressure RO separation into one compact industrial platform. A PLC touch screen control system delivers automatic operation, sensor monitoring, and backwash functions, while an independent CIP cleaning loop supports periodic membrane chemical cleaning. With a feed water TDS tolerance of up to 8,000 ppm and a desalination rate of 97–99%, the FG-BWRO-5000 produces low-TDS permeate suitable for industrial process water, community supply, agricultural irrigation, and small-scale drinking water applications. Customized configuration is available to match site-specific water quality and recovery requirements.

Key Attributes
Attribute | Specification |
Productivity | 5,000 LPH |
Processing Type | Reverse Osmosis |
Voltage | 110 V / 220 V / 380 V |
Power | 7.75 kW |
Core Components | Gearbox, Pressure vessel, Pump, Gear, Bearing |
Machinery Test Report | Provided |
Warranty | 1 Year |
Video Outgoing-Inspection | Provided |
Weight | 2,500 kg |
Material | 304 Stainless Steel Frame, FRP Pressure Vessel, UPVC Piping |
Control System | PLC Touch Screen Automatic Control |
Feed Water TDS | ≤ 8,000 ppm |
Desalination Rate | 97% – 99% |
Raw Water Source | Brackish well water, underground salty water |
Features | Automatic running, anti-scaling dosing system, CIP cleaning function |
Customization | Support customized configuration |
Treatment Process
Raw water pump → Automatic sand filter → Activated carbon filter → Softener → Precision filter → High-pressure pump → RO membrane system → Product water.
The pretreatment train (multi-media filter, activated carbon filter, and optional softener) removes sediment, chlorine, odor, and hardness before the precision filter traps fine particles ahead of the high-pressure pump. The antiscalant dosing system injects scale inhibitor upstream of the RO membranes to control CaCO₃, CaSO₄, and silica precipitation, extending membrane service life. The independent CIP circuit enables chemical cleaning without dismantling the membrane array.

Machine Components & Functional Modules
Control Valves: Manual and automatic valve groups for feed, concentrate, and flush line regulation.
Dosing System: Chemical dosing pump and PE tank for automatic antiscalant injection; dosing rate adjustable to raw water quality.
Auto Control Valves: Automatic backwash valve heads on multi-media and activated carbon filters for unattended regeneration.
Flow Meter: Permeate and concentrate flow indication for recovery monitoring and membrane performance verification.
EDI Module (Optional): Electrodeionization polishing unit for ultrapure water requirements when downstream conductivity specifications demand it.
Filter Cartridges: 20 μm and 5 μm precision filter elements for final particulate protection of RO membranes.
RO Controller: Dedicated reverse osmosis controller with TDS/conductivity display, alarm indicators, and flush set points.
UF Membrane (Pretreatment Option): Ultrafiltration modules available for feed water with elevated turbidity or colloidal load.
High-Pressure Pump: Vertical multistage centrifugal pump delivering stable RO operating pressure with low noise and high efficiency.
Electrical Control Cabinet: PLC-based panel with HMI, motor protection, and interlocked safety logic.

Technical Specifications — FG-BWRO-5000
Parameter | Specification |
Production Capacity | 5,000 LPH |
Model | FG-BWRO-5000 |
Inlet Water | Brackish water (TDS 1,000 – 10,000 ppm) |
Raw Water Pump | CHL8-40 / 1.5 kW |
HP Pump | CDLF8-14 / 5.5 kW |
CIP Pump | CNP CHL4-40 / 0.75 kW |
RO Membrane | Vontron LP21-8040 (8-inch, low-pressure brackish water element) |
Membrane Housing | 8040, 300 psi / 450 psi |
Flow Meter | 10 T / 8 T |
Pressure Gauge Range | 1 MPa / 2.5 MPa |
Pressure Switch | 30 bar & 6 bar |
Inlet Valve | Solenoid valve, 2 inch |
Flush Valve | Solenoid valve, 2 inch |
Waste Water Adjust Valve | DN50 |
Frame | SUS304 |
UV Sterilizer | 165 W (55 W × 3 lamps), without electronic control |
Desalination Rate | 97% – 99% |
Recovery Rate | 50% – 75% |
Membrane Element Reference
The Vontron LP21-8040 is a low-pressure aromatic polyamide composite RO element with an active membrane area of 365 ft² (33.9 m²), average permeate flow of 9,600 GPD (36.3 m³/d), and stable rejection rate of 99.5%, suitable for brackish water and high-concentration brackish water service.
FG Water BWRO Series — Nominal Capacity Matrix
FG Model | Nominal Capacity (LPM / GPM) | Nominal Capacity(TPH / GPD) | No. of 8″ Membranes |
FG-BWE-814 | 71.9 / 19 | 4.3 / 27,400 | 4 |
FG-BWE-815 | 89.9 / 23.8 | 5.4 / 34,200 | 5 |
FG-BWE-816 | 107.9 / 28.5 | 6.5 / 41,100 | 6 |
FG-BWE-822 | 71.9 / 19 | 4.3 / 27,400 | 4 |
FG-BWE-823 | 107.9 / 28.5 | 6.5 / 41,100 | 6 |
FG-BWE-824 | 143.8 / 38.1 | 8.6 / 54,800 | 8 |
FG-BWE-825 | 179.8 / 47.6 | 10.7 / 68,500 | 10 |
FG-BWE-826 | 215.8 / 57.1 | 12.9 / 82,200 | 12 |
FG-BWE-832 | 107.9 / 28.5 | 6.5 / 41,100 | 6 |
FG-BWE-833 | 161.8 / 42.8 | 9.7 / 61,600 | 9 |
FG-BWE-834 | 215.8 / 57.1 | 12.9 / 82,200 | 12 |
FG-BWE-835 | 269.7 / 71.3 | 16.2 / 102,700 | 15 |
FG-BWE-836 | 323.6 / 85.6 | 19.4 / 123,300 | 18 |
FG-BWE-837 | 377.6 / 99.9 | 22.7 / 143,800 | 21 |
FG-BWE-843 | 215.8 / 57.1 | 12.9 / 82,200 | 12 |
FG-BWE-844 | 287.7 / 76.1 | 17.2 / 109,600 | 16 |
FG-BWE-845 | 359.6 / 95.1 | 21.6 / 137,000 | 20 |
FG-BWE-846 | 431.5 / 114.2 | 25.9 / 164,000 | 24 |
FG-BWE-847 | 503.4 / 133.2 | 30.2 / 191,800 | 28 |
FG-BWE-849 | 647.3 / 171.2 | 38.8 / 246,600 | 36 |
FG-BWE-8412 | 863 / 228.3 | 51.8 / 328,000 | 48 |
Applications
Brackish well water and underground salty water treatment for factory and community supply.
Industrial process water preparation, boiler feedwater make-up, and cooling tower make-up.
Agricultural irrigation water desalination for salinity-affected soils.
Small-scale drinking water production for schools, restaurants, and residential compounds (with UV and post-treatment options).
Pre-treatment for EDI or mixed-bed polishing where ultrapure water is required.

Features & Advantages
Automatic PLC Operation: Touch screen HMI with sensor monitoring, alarm logic, and backwash sequencing reduces manual intervention.
Integrated Anti-Scaling Protection: Automatic chemical dosing system and CIP cleaning function extend membrane service life and stabilize recovery.
High-Tolerance Brackish Water Design: Feed TDS up to 8,000 ppm with 97–99% desalination, supported by low-pressure LP21-8040 elements for energy-efficient operation.
Corrosion-Resistant Construction: 304 stainless steel frame, FRP pressure vessels, and UPVC piping for durable service in aggressive brackish water environments.
Skid-Mounted Plug-and-Play Configuration: Pre-assembled and factory-tested; on-site connection limited to raw water inlet, power supply, and product water outlet.
Customizable Configuration: Pretreatment options (softener, UF), EDI polishing, and recovery adjustments available to match project-specific water analysis.
Warranty & Support
1-year warranty on main components. Factory machinery test report and outgoing-inspection video provided. Technical documentation and spare-part support available.
Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target