Product System
Containerized UF+RO at 36 m³/h: A Rapid-Deployment Water Package for EPC and Mining Camp Projects
Factory-built UF+RO container rated 36 m³/h. Handles high-turbidity surface water and brackish well water. Rapid deployment, low civil work, FAT & commissioning support. For EPC and remote camp water.
Containerized UF+RO at 36 m³/h: A Rapid-Deployment Water Package for EPC and Mining Camp Projects
For EPC subcontractors and mining operations that need reliable water from high-turbidity surface sources or brackish wells — with minimal civil works and a schedule that cannot wait for site-built construction — the FG-UF-RO-C36 delivers ultrafiltration pretreatment and reverse osmosis in a single factory-tested shipping container, rated at 36 m³/h.
Why EPC and Mining Projects Move to Containerized UF+RO Delivery
On a fast-track EPC schedule, water infrastructure is rarely the most technically complex package — but it is often the one that exposes the project to the most schedule risk. Site-built treatment plants depend on civil works, local labor coordination, and commissioning activity in heat, dust, and logistics conditions that are difficult to control. A factory-built containerized plant shifts a large share of that work into a controlled workshop environment before the container ever reaches site.
Mining camps face a parallel set of constraints. Many are located far from centralized treatment infrastructure, and the raw water source — surface runoff, a river, a lake, or a saline borehole — can vary sharply in turbidity and salinity. The FG-UF-RO-C36 addresses both dimensions in one integrated package: UF removes suspended solids, colloids, bacteria, and most viruses, producing turbidity ≤1 NTU and microbial rejection ≥99% as pretreatment before the RO stage. The RO section then reduces dissolved salts, with a 50–75% recovery range for brackish water.
What the C36 Actually Is — and What It Is Not
Verified integrated configuration
All core process units are installed inside a standard shipping container: UF membrane racks, feed and backwash pumps, cartridge filtration, RO high-pressure section, PLC control cabinet, and instrumentation.
Verified Attribute | Verified Specification |
System type | Pretreatment + RO integrated containerized plant |
Rated productivity | 36 m³/h |
UF membrane material | PVC hollow fiber |
UF product water turbidity | ≤1 NTU |
UF microbial rejection | ≥99% |
RO recovery (brackish water) | 50–75% |
Control | Siemens PLC + HMI, Auto & Manual |
Weight | 1,500 kg |
Warranty | 1 year |
Test documentation | Machinery test report; video outgoing inspection |
The figures below define how this 36 m³/h rating should be read and what must come from the site before RO performance can be confirmed. No value here is invented: where a number is not published, it is shown as a project input to be verified.
Item | Status on this page |
Rated capacity — 36 m³/h | Nominal system throughput. Whether it is stated as feed-water flow or permeate flow must be confirmed against the project datasheet; achievable permeate volume depends on the design recovery. |
Applicable raw-water sources | High-turbidity surface water and brackish borehole / well water (as positioned on this page). |
Design feed-water TDS, SDI, turbidity, temperature | Project-specific input from a water analysis; not a fixed published figure here. |
Permeate quality (TDS / conductivity) | Set from the confirmed target product-water quality; not a single standardized figure. |
RO recovery (brackish water) | 50–75% as published; exact value depends on feed TDS and configuration. |
UF product turbidity / microbial rejection | ≤1 NTU / ≥99% (pretreatment) as published. |
Weight | 1,500 kg as published; container dimensions, lifting points and connection locations to be confirmed from the general arrangement (GA) drawing. |
Standard integrated supply | UF racks, feed/backwash pumps, cartridge filtration, RO section, Siemens PLC + HMI, instrumentation, factory-tested container. |
Post-treatment (remineralisation / disinfection) | Not stated as standard; added only as project-specific scope. |
Concentrate / brine management | Not stated as standard; discharge consent and management are project scope. |
Reading the 36 m³/h rating together with these design inputs lets engineers and EPC buyers judge project fit before RFQ, rather than treating throughput as a standalone claim.

The TDS boundary — stated as a scoping condition, not a promise
The product documentation does not publish a single maximum feed TDS figure for the RO section. This page therefore treats TDS as a project-specific design input, not a standardized claim. For quotation and scope alignment:
The C36 is positioned for brackish water desalination, drinking water treatment, and industrial water purification where rapid deployment and low civil work are required.
Feed TDS, temperature, and site-specific water chemistry must be confirmed before RO performance is guaranteed. Do not assume that “brackish” covers any salinity level; if the feed TDS or variability is outside what the project documents support, the RO stage may require a different configuration or additional pretreatment.
How the C36 differs from a skid-mounted BWRO
A skid-mounted BWRO — such as the FG-BWRO-824/826 — is an RO-centric packaged system intended for sites that already deliver feedwater meeting the RO’s SDI, turbidity, iron, and chlorine limits, and that have a suitable enclosure. The C36 is a pretreatment-integrated plant: UF is built in precisely because the raw water may not meet those limits. The two products solve different project boundaries and must not be specified interchangeably. If the source is high-turbidity surface water, or the site needs a self-contained treatment train rather than an RO skid, the C36 is the appropriate starting point.
Where the 36 m³/h Container Fits: EPC Subcontracting and Mining Camp Water Supply
EPC subcontractors: moving water off the critical path
For an EPC subcontractor responsible for a water package within a larger project, the C36’s value is not only its treatment capability — it is the delivery model. A factory-built, pre-tested container can be shipped, positioned, and tied in with reduced site labor and reduced commissioning exposure compared with a stick-built plant. The Siemens PLC + HMI supports auto and manual operation, and the system is designed for easy transportation, fast installation, and compact layout. For projects that need a bridge water supply during construction, or a modular plant that can be expanded later, the container format allows phased capacity without re-engineering the entire water infrastructure.
Mining camps: surface water and saline boreholes in one treatment train
Mining camp water sources are often characterized by high and variable turbidity — runoff, river water, or lake water — or by saline borehole water that must be desalinated for potable use. The C36’s UF stage is specifically positioned to handle high-turbidity surface water and biologically treated effluent as RO pretreatment, while the RO stage addresses dissolved salinity. The integrated UF+RO train means the camp does not need to procure, install, and commission a separate pretreatment package before the RO can operate.
System Configuration and Scope Boundaries for RFQ Alignment
The C36 is a pre-engineered platform, but several scope layers remain project-specific. The table below separates what is verified as integrated from what must be confirmed during quotation.
Scope Layer | Verified Integrated Scope | Project-Specific Confirmation Needed |
UF Pretreatment | PVC hollow-fiber UF, turbidity ≤1 NTU, microbial rejection ≥99% | Raw-water turbidity range and whether coagulant/flocculant dosing is required upstream |
RO Stage | Brackish water RO, recovery 50–75% | Feed TDS, temperature, and target product TDS — these determine membrane selection and operating pressure |
Pumps & Filtration | Feed/backwash pumps, cartridge filtration | Site electrical supply (voltage/frequency) and whether VFD or soft-start is required |
Control System | Siemens PLC + HMI, auto & manual | Whether client SCADA requires Modbus/RS485 or remote telemetry |
Container & Logistics | Standard shipping container, factory-tested | Shipping dimensions, lifting/offloading plan, and site access for container delivery |
Post-treatment | Not stated as standard | Whether remineralisation, disinfection (chlorine/UV), or product-water storage is required |
Brine / Concentrate | Not stated as standard | Discharge consent conditions and whether concentrate management is in the project scope |
FAQ: What EPC Buyers and Mining Operators Ask Before Specifying
Q1: Can the C36 treat surface water with high turbidity directly?
The UF stage is designed to remove suspended and particulate matter, including colloids and silt, and to produce turbidity ≤1 NTU as RO pretreatment. However, the specific raw-water turbidity range must be confirmed against site data. If turbidity spikes far beyond the UF’s design envelope, upstream clarification or media filtration may be required. Do not assume the container accepts any turbidity level without engineering review.
Q2: What feed TDS can the RO section handle?
The product documentation does not publish a single maximum TDS for the RO section. The C36 is positioned for brackish water desalination, but feed TDS must be treated as a project-specific design input. For a quotation, provide the measured TDS, its variability, temperature, and target product-water quality. The RO configuration, membrane selection, and operating pressure will be confirmed against those inputs.
Q3: Is the C36 the same as a containerized BWRO skid?
No. A containerized BWRO skid is typically an RO-centric system for feedwater that already meets RO limits. The C36 is a UF+RO integrated plant with built-in pretreatment, intended for raw water that may not consistently meet RO feed requirements. The scope boundary is different, and the two should not be compared on price alone without aligning the pretreatment responsibility.
Q4: What FAT and commissioning support is associated with the container?
The product documentation states that a machinery test report and video outgoing inspection are provided. The scope of factory acceptance testing, site installation acceptance testing, and on-site commissioning must be defined in the project’s technical specification. For EPC projects, FAT protocols and IAT criteria should be agreed before fabrication.
Q5: Does the C36 include post-treatment or brine management?
Standard integrated scope does not list remineralisation, disinfection, or brine/concentrate handling. If the project requires potable-water conditioning or a specific concentrate discharge arrangement, these must be added as project-specific scope items and reflected in the RFQ.
Q6: What is the footprint and weight for logistics planning?
The system is integrated in a standard shipping container and weighs 1,500 kg. The exact container dimensions, lifting points, and connection locations must be confirmed from the project’s general arrangement drawing during detailed engineering.
Inquiry CTA
Send your raw-water analysis, required daily volume, site location, and project schedule to FG Water’s containerized systems team. Include TDS, turbidity range, temperature, target product-water quality, and whether post-treatment or brine management is in your scope. The engineering team will confirm whether the FG-UF-RO-C36 fits the project boundary, or whether a different pretreatment or RO configuration is required.
Email: [email protected]
View Full Specifications: https://www.fgwater.com/product-system/827.html
View Skid-Mounted BWRO Series: https://www.fgwater.com/product-system/831.html
Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target